LC_X80 Basic Serial Command Functional Specifications
13/23
6.27 POWER MANAGEMENT READY Command
Command
C2A[CR]
Detail
Set Power Management function to ready status
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.28 POWER MANAGEMENT CANCEL Command
Command
C2B” [CR]
Detail
Set Power Management function to off status
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.29 POWER MANAGEMENT SHUTDOWN Command
Command
C2E” [CR]
Detail
Set Power Management function to Shutdown mode.
This status is stored in EEPROM and retained regardless of Power OFF/ON
operation.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.30 D.ZOOM + Command
Command
C30 [CR]
Detail
Enter Digital Zoom mode and expand image size
This command works the same way as “D.ZOOM ” button of the remote control.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.31 D.ZOOM - Command
Command
C31 [CR]
Detail
Enter Digital Zoom mode and reduce image size
This command works the same as “D.ZOOM ” button of the remote control.
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]
6.32 INPUT 3 VIDEO Command
Command
C33 [CR]
Detail Select Video input in Input 3
Acceptable [ACK] [CR]
Response
Unacceptable
“?” [CR]