LC_XG400L Basic Serial Command Functional Specifications
11/24
6.10 INPUT 3 Command
Command “C07” [CR]
Detail
Select Input 3. This command works differently from the command by “Input 3”
key of the remote control. When Input 3 has been selected, this command does
not execute the source switching; just for switching to Input 3.
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.11 NETWORK Command
Command “C08” [CR]
Detail Select Network Input
Acceptable [ACK] [CR]
Response
Unacceptable “?” [CR]
6.12 VOLUME + Command
Command “C09” [CR]
Detail
Volume Up.
This command operates the same way as VOLUME + button of the projector and
remote control.
Acceptable [ACK] [CR]
Response
Unacceptable “?”[CR]
6.13 VOLUME Command
Command “C0A” [CR]
Detail
Volume Down
This command operates the same way as VOLUME – button of the projector and
remote control.
Acceptable [ACK] [CR]
Response
Unacceptable “?”[CR]
6.14 SOUND MUTE ON Command
Command “C0B” [CR]
Detail
Sound Mute ON.
This command works the same way as “MUTE” button of the remote control for
Mute ON, but does not work for Mute OFF.
Acceptable [ACK] [CR]
Response
Unacceptable “?”[CR]
6.15 SOUND MUTE OFF Command
Command “C0C” [CR]
Detail
Sound Mute OFF.
This command works the same way as “MUTE” button of the remote control for
Mute OFF, but does not work for Mute ON.
Acceptable [ACK] [CR]
Response
Unacceptable “?”[CR]